OCEOS/oceos fdir

From wiki
Jump to navigation Jump to search

OCEOS Fault Detection, Isolation and Recovery (FDIR)

FDIR Introduction

Hardware and software faults can occur that affect the behavior of the system. To detect such faults and anomalies, as scheduling proceeds OCEOS automatically checks that its key data areas have not been corrupted and that uses of resources are within their prescribed bounds. Parameters passed to directives are checked for consistency with the values originally declared in the application configuration.
Once detected, OCEOS provides five levels of responses to faults and anomalies:
Level 1: The status code returned by a directive indicates that there was a problem

The status code returned by a directive should always be checked.
This code identifies whether the directive succeeded and if not indicates the reason for the failure.
This is the only response made when the anomaly is an invalid parameter to a directive. It is combined with responses from other levels if a directive fails for some other reason.

Level 2: An appropriate log entry is added to the system log.

The log entry contains a code identifying the problem and a 32-bit timestamp.
This response occurs in addition to the Level 1 response if a directive fails due to an internal factor such as the maximum number of jobs for a task being already created or a data queue being full.
This response also occurs when a task misses its deadline or any unexpected behavior. This response is often accompanied by a Level 3 response.

Level 3: The system state variable is updated and a user defined problem handling function called.

The system state variable consists of 32 flags each indicating a particular problem type. It is reset by oceos_init(). A copy of this variable is also maintained. Both variables may be reset by the ASW. This response occurs also in most circumstances where the Level 2 response occurs.

Level 4: An ASW problem handling function is called by OCEOS.

A problem handling function can be identified in the application configuration structure passed to oceos_init() and if present may be called by OCEOS. This function can read the system log and system state variable, read the task timing and other information, enable and disable tasks, reset counting semaphores and data queues, and if necessary exit OCEOS. It can reset the system state variable, it is recommended that the copy of the system state variable not be reset so as to provide a longer term record of problems.
This response occurs also in most circumstances where the Level 3 response occurs

Level 5: OCEOS exits and returns to the ASW with an appropriate status code.

The status code in effect provides a Level 1 response to the oceos_start() directive used by the ASW to start OCEOS. In normal circumstances OCEOS never returns to the ASW.

This response by OCEOS only occurs when it detects that one of its essential internal elements has been corrupted. Depending on the severity of this corruption a Level 2 response may also be provided if possible, and the system state variable may also be updated. The user defined problem handling function is not called.

If OCEOS exits the ASW can inspect the system log and system status variable, and also the task timings and other information maintained by OCEOS. The ASW can decide what corrective action should be taken and may resume scheduling with a call to oceos_start(). The ASW can also inspect these items during scheduling, allowing it check the state of the system at any time.

This approach provides a graduated response by OCEOS to problems and allows some problems be isolated and recovered by, for example, disabling tasks or clearing a data queue if an appropriate problem handling function is provided as part of the ASW. The ASW may also check system information at any time to determine whether things are proceeding as expected.

Note

The ASW may set up a watchdog timer which will cause a system reset if a certain time elapses before it is reset. By using a lowest priority task to reset the watchdog failure of higher priority tasks to complete within their expected time can be detected. In OCEOS the lowest priority task, if it is the only task at that priority, is allowed to run forever and may be used to reset the watchdog.
OCEOS provides watchdog timer functionality for GR716 target and not part of OCEOS for other targets.

The log area contains the System State Variable, the system log, and the optional context switch log.

The OCEOS system state variable contains flags that indicate a certain problem has occurred. It is automatically updated by OCEOS using ‘OR’ to avoiding losing information, typically a user defined function is called to deal with the problem.

Two sets of flags are kept as part of the system state variable. One accumulates indicators of all problems that have occurred, and typically is reset by the application only after a restart. The other indicates current problems, and typically is reset by the user defined problem handling function. For system state variable location please see HERE.
Application developer can provide system status mask that is used to AND with system status variable and if not zero, calls user defined error handling function.

/**
 *
 * SYSTEM STATUS VARIABLE FLAGS
 *
 * These are stored in the 32-bit system status variable 
 * and updated by OCEOS when a problem is detected.
 * Resetting them is the responsibility of the application.
 */

#define  STATUS_MASK_NORMAL      0xffffffffU    // not used at present

#define  STATUS_NORMAL                    0U    // No flag set
#define  STATUS_EDAC_INTERNAL             1U    // Uncorrectable error in internal memory
#define  STATUS_EDAC_EXTERNAL             2U    // Uncorrectable error in external memory
#define  STATUS_MEM_PROT_1                4U    // Invalid access memory protection unit 1
#define  STATUS_MEM_PROT_2                8U    // Invalid access memory protection unit 2
#define  STATUS_DISABLED_TASK_START    0x10U    // An attempt to start a disabled task
#define  STATUS_TASK_JOB_LIMIT_OVER    0x20U    // An attempt to execute a task when its jobs limit is already reached.
#define  STATUS_JOB_OVER_TIME          0x40U    // Job time from creation to completion exceeds allowed maximum for a task.
#define  STATUS_JOB_INTERVAL_SHORT     0x80U    // Minimum time between job creations is less than the allowed minimum for task
#define  STATUS_READYQ_FULL           0x100U    // Ready queue unable to accept job as result of being full
#define  STATUS_MUTEX_ALREADY_HELD    0x200U    // Mutex wait() when mutex already held
#define  STATUS_MUTEX_NOT_HELD        0x400U    // Mutex signal() when not already held
#define  STATUS_MUTEX_NOT_RETURNED    0x800U    // Mutex not returned before job terminates
#define  STATUS_SEMAPHORE_JOBS_FULL  0x1000U    // Attempt to add job to semaphore pending list when list full
#define  STATUS_DATAQ_FULL           0x2000U    // Data queue write when queue already full
#define  STATUS_DATAQ_JOBS_FULL      0x4000U    // Attempt to add job to queue pending list when list full
#define  STATUS_TIMED_JOBS_FULL      0x8000U    // Timed jobs queue write when queue already full
#define  STATUS_TIMED_JOB_LATE      0x10000U    // Timed jobs queue late job transfer to scheduler
#define  STATUS_TIMED_OUTPUT_FULL   0x20000U    // Timed output queue write when queue already full
#define  STATUS_TIMED_OUTPUT_LATE   0x40000U    // Timed output late
#define  STATUS_TIMED_ACTION_LATE   0x80000U    // Timed action late
#define  STATUS_READYQ_NO_REMOVE   0x100000U    // Remove job from ready queue failed
#define  STATUS_OLDJOB_NOT_EXEC    0x200000U    // Job being pre-empted was not executing
#define  STATUS_SYSTEM_ERROR       0x400000U    // ERROR was handled by default trap handler
#define  STATUS_BAD_LOG          0x80000000U    // System log problem
#define  STATUS_INVALID          0xffffffffU    // System status invalid

FDIR Configuration

User can provide function, that is called in case of system ERROR

/**
 * User to implement in case of system error;
 * Comment it out if not used and set field system_error_function in app_config to NULL
 */
void oceos_on_error(void* ptr) {
  //  Application ERROR Handling code
  return;
}
...
/*
 * Create the application configuration structure
 */
struct application_configuration           app_config = {0};
app_config.system_error_function         = &oceos_on_error;               // NULL => ignore

API Functions

API Functions
Directive Description main task IRQ handler
oceos_system_state_get() Get the value of the system state variable * * *
oceos_system_state_set() Set system state variable * * *
oceos_system_watchdog_init() Initialize the watchdog * * *
oceos_system_watchdog_enable() Enable the watchdog * * *
oceos_system_watchdog_disable() Disable the watchdog * * *
oceos_system_watchdog_ticks_remaining() Get the number of ticks to watchdog timeout * * *
oceos_system_watchdog_reset() Reset the watchdog * * *

oceos_system_state_get()

Header File
system_log.h

Description
Returns the value of the system state variable.

Prototype

U32_t                   oceos_system_state_get(void);

Parameters

Parameter Description

Returns
This function returns U32_t.

U32_t Description
STATUS_INVALID Failed to read System State Status
>= 0 System State Status

Example Usage

 U32_t status;
 status = oceos_system_state_get();
 if (STATUS_INVALID == status) {
   // Handle ERROR
 }

oceos_system_state_set()

Header File
system_log.h

Description
Set system state variable and save previous setting to System State variable OLD. Setting to zero means resetting the System State status

Prototype

enum DIRECTIVE_STATUS   oceos_system_state_set(
    U32_t new_state              // new value of system state variable
);

Parameters

Parameter Description
new_state New value of system state variable

Returns
This function returns enum DIRECTIVE_STATUS.

enum DIRECTIVE_STATUS Description
INCORRECT_STATE System Meta pointer is NULL or Log pointer is NULL
SUCCESSFUL All OK

Example Usage

enum DIRECTIVE_STATUS status;
U32_t sys_state = 0;
status = oceos_system_state_set(sys_state);
if (SUCCESSFUL != status) {
  // Handle ERROR
}

oceos_system_watchdog_init()

Header File
FDIR.h

Description
FOR GR716 ONLY
This directive initializes the watchdog for GR716 at 0x80003070. The watchdog window reload value is in the control register. Large window sizes make resets more likely.

Prototype

enum DIRECTIVE_STATUS   oceos_system_watchdog_init(
    BOOLE_t enable,            // enabled initially
    U32_t timeout,             // watchdog timeout
    U8_t window_size           // watchdog window
 );

Parameters

Parameter Description
enable TRUE to enable watchdog at initialization
timeout Watchdog timeout
window_size Watchdog windows size

Returns
This function returns enum DIRECTIVE_STATUS.

enum DIRECTIVE_STATUS Description
INVALID_NUMBER Parameter check failed
SUCCESSFUL All OK

Example Usage

 enum DIRECTIVE_STATUS status;
 status = oceos_system_watchdog_init(TRUE, 1000, 0xFF);
 if (SUCCESSFUL != status) {
   // Handle ERROR
 }

oceos_system_watchdog_enable()

Header File
FDIR.h

Description
FOR GR716 ONLY
This directive enables the watchdog for GR716 at 0x80003070 which will use timeout and window values setup previously.

Prototype

enum DIRECTIVE_STATUS  oceos_system_watchdog_enable();

Parameters

Parameter Description

Returns
This function returns enum DIRECTIVE_STATUS.

enum DIRECTIVE_STATUS Description
SUCCESSFUL If All OK

Example Usage

num DIRECTIVE_STATUS status;
status = oceos_system_watchdog_enable();

oceos_system_watchdog_disable()

Header File
FDIR.h

Description
FOR GR716 ONLY
Prototype

Parameters

Parameter Description

Returns
This function returns enum DIRECTIVE_STATUS.

enum DIRECTIVE_STATUS Description
INCORRECT_STATE If system Meta pointer is NULL or

Init pointer is NULL or Start up phase check fail or Fixed data checksum failed (check log)

INVALID_NAME If Start Sentinel for fixed area is corrupt or

Start Sentinel for dynamic area is corrupt

INVALID_NUMBER If Configuration and actual parameters do not match

(In configuration file was defined 5 tasks, but created less)

SUCCESSFUL If All OK

Example Usage

oceos_system_watchdog_ticks_remaining()

Header File
FDIR.h

Description
FOR GR716 ONLY
Prototype

Parameters

Parameter Description

Returns
This function returns enum DIRECTIVE_STATUS.

enum DIRECTIVE_STATUS Description
INCORRECT_STATE If system Meta pointer is NULL or

Init pointer is NULL or Start up phase check fail or Fixed data checksum failed (check log)

INVALID_NAME If Start Sentinel for fixed area is corrupt or

Start Sentinel for dynamic area is corrupt

INVALID_NUMBER If Configuration and actual parameters do not match

(In configuration file was defined 5 tasks, but created less)

SUCCESSFUL If All OK

Example Usage

oceos_system_watchdog_reset()

Header File
FDIR.h

Description
FOR GR716 ONLY
Prototype

Parameters

Parameter Description

Returns
This function returns enum DIRECTIVE_STATUS.

enum DIRECTIVE_STATUS Description
INCORRECT_STATE If system Meta pointer is NULL or

Init pointer is NULL or Start up phase check fail or Fixed data checksum failed (check log)

INVALID_NAME If Start Sentinel for fixed area is corrupt or

Start Sentinel for dynamic area is corrupt

INVALID_NUMBER If Configuration and actual parameters do not match

(In configuration file was defined 5 tasks, but created less)

SUCCESSFUL If All OK

Example Usage